Radwag MYA 5.3Y.F1 Microbalance Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Radwag MYA 5.3Y.F1 Microbalance. RADWAG MYA 5.3Y.F1 Microbalance User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 198
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - BALANCES 3Y SERIES

User manual no: IMMU-01-03-08-14-EN BALANCES 3Y SERIES − ultra-microbalances UYA 3Y − microbalances MYA 3Y BALANCE

Página 2

- 10 - 2. UNPACKING AND INSTALLATION Carefully unpack the balance, remove plastic, cardboard and foil packagings together with protective elements

Página 3

- 100 - The adapter has been designed to minimize evaporation occurring in liquid handling procedures. It consists of a minimized weighing chamber in

Página 4

- 101 - following step - <Weighing sample C1/V1/N1>. Description of texts: C1 – channel number; V1 – number of volume for a channel; N1 – num

Página 5

- 102 - 8 0.998 g 1000.82389 µl 9 0.998 g 1000.82389 µl

Página 6

- 103 - 25. DIFFERENTIAL WEIGHING Working mode < Differential weighing> enables analysing changes of mass in a single sample or multiple sa

Página 7

- 104 - 1. Setup – access to balance’s menu 2. Series 3. Sample 4. Weighing A 5. Weighing B 6. Weighing T+A 7. Delete value 25.1. Additiona

Página 8 - 1. GENERAL INFORMATION

- 105 - Below list provides the functions of only those soft keys, that are absent in working mode “Weighing” Weighing A Start sampling of initial

Página 9

- 106 - 25.3. Introducing a series to the Database of Series Database of series comprises series and samples which are components of a series. While

Página 10

- 107 - 25.4. An example of process for differential weighing mode On activating DIFFERENTIAL WEIGHING mode: • Select information to be displayed in

Página 11

- 108 - Weighing A On selecting an option, the balance moves to the first sample on the list, for which weighing <A> is still to be carried

Página 12 - 3. BALANCE DESIGN

- 109 - The software automatically moves to the following sample in a series. Follow above procedure and weigh the following samples. The process ca

Página 13

- 11 - 2.1. Balance cleaning 1. Disassembly the weighing pan and portable elements. Use the most gentle movements so as not to damage the mechanis

Página 14 - 4. STARTUP

- 110 - <VALUE>, or the data on ambient conditions is automatically acquired from the ambient conditions module and displayed for confirmation

Página 15 - 6. SOFTWARE STRUCTURE

- 111 - In order to preview detailed information on a sample, press field with its name. The opened window contains the following data: In case t

Página 16 - 7. SOFTWARE WEIGHING WINDOW

- 112 - it is the 1 measuring cycle type B, and <3> means, that the <NUMBER OF REPETITIONS> for this process is set to <3> (3 cycle

Página 17 - 8. LOGGING

- 113 - On previewing a specific weighing, a window is opened with data and values on the weighing process. Numbers displayed next to weighing data &

Página 18 - 9. OPERATING USER MENU

- 114 - 25.7. Deleting a value The option, in case of an error, enables deleting last weighing record added to the database. It applies to all proc

Página 19

- 115 - 25.8. Printouts Option Printouts enables setting the contents of printouts in a standard printout and also determining non-standard printouts

Página 20 - 10. WEIGHING

- 116 - • Packaging • Universal variable 1…5 • Net • Tare • Non-standard printout − Weighing B • Weighing B • Date • Time • Level status •

Página 21

- 117 - 26. STATISTICAL QUALITY CONTROL - SQC Working mode < Statistical Quality Control > is intended to carrying out different types of pr

Página 22

- 118 - 26.1. Working mode activating procedure Procedure: • While in the main window, press soft key located in the upper bar of the display, w

Página 23

- 119 - Max Value of +T1 error (specified in % of nominal mass) Unit Measuring unit of a product: [g] Caution: Editing product records in the da

Página 24

- 12 - 3. BALANCE DESIGN 3.1. Dimensions 3.2. Interfaces Available interfaces overview 1 – Ethernet RJ45 2 – RS232 interface (COM

Página 25 - !> symbol

- 120 - 26.2. Additional settings of the SQC mode The additional settings enable adjusting the working mode to user’s needs and requirements. Acc

Página 26

- 121 - Messages displayed during a control process: Batch quantity 1 / 10 - A command on process course and the quantity of all measurements in a t

Página 27 - • AUTOTARE

- 122 - ---------Measurement 4 --------------- Net 50.038 g ---------Measurement 5

Página 28 - • AUTOMATIC MODE

- 123 - 27. DATABASES Software of balances 3Y series features the following databases < >: PRODUCTS WEIGHING RECORDS CLIENTS FORMU

Página 29 - • NON-STANDARD PRINTOUT

- 124 - 27.1. Processes carried out on databases Databases can be operated only by an authorized personnel. In order to edit databases proceed as

Página 30 - • MODE

- 125 - The following processes can be carried out in almost any of databases: 1. Adding entry to a database < > 2. Searching for a record in

Página 31

- 126 - 10. Tare [product’s tare value, set automatically on selecting a product from the database] 11. Price [Unit price

Página 32

- 127 - • Enter submenu < Databases> • Enter database of < Weighing records> and press desired entry (record). List of parameters f

Página 33

- 128 - 27.5. Formulation Database of Formulas contains list of designed formulas / mixtures, which can be prepared by weighing each of formulation

Página 34 - 11. ADJUSTMENT

- 129 - 27.7. Reports from density Reports from density contain data on carried out density determination processes of solids, liquids and air. Each

Página 35

- 13 - Interfaces RS232 and WE/WY RS232 - socket DB9/M (male), front view: Pin2 - RxD Pin3 - TxD Pin5 - GND IN/OUT, RS232 socket DSUB15/F (fe

Página 36

- 130 - 27.8. Pipettes Database of Pipettes contains records and specification on pipettes to be calibrated. Procedure • Enter submenu < Data

Página 37 - Hint:

- 131 - 27.9. Reports from pipette calibration processes Reports contain data on completed pipette calibration processes. In case of multichannel

Página 38 - 12. USERS

- 132 - • If a series already exists in the database, press field with its name to edit data that is optionally editable List of parameters define

Página 39 - 13. ACCESS LEVEL

- 133 - 14. Number of T2+ errors [Quantity of +T2 errors] 15. A chart from control processes 16. A chart from control processes with limit

Página 40

- 134 - 4. Next control – a field for entering expiry date of the minimum sample. 2 weeks before the expiry date the pictogram on minimum sample sta

Página 41 - 14. PROFILES

- 135 - measuring range of a balance (the <TARE> button applied), as well as on weighing samples without the packaging (the <TARE> button

Página 42

- 136 - Procedure • Enter submenu < Databases>, and press < Packages> field • Press < Add > key should a new packaging be adde

Página 43

- 137 - • In the <Record editing> field press <Template> key • A window is opened for creating an optional printout • While design

Página 44

- 138 - Net weight: 94.147 Carried by: Admin T

Página 45

- 139 - 27.18.1. Export database of weighing records to file All carried out measurements are saved and stored in a database. The balance enables

Página 46

- 14 - 4. STARTUP • On plugging the balance to mains, instrument’s diode ON/LOAD located on indicator’s housing is lit up. • Press powering key

Página 47

- 140 - • Set option and click <Export weighings>, software will automatically export weighing database, • Upon completion a respective messa

Página 48

- 141 - Upon confirmation the software deletes data and displays a summary message: Upon confirmation the software returns to a previous window.

Página 49

- 142 - 27.18.3. Delete weighments and reports Function allows to delete a given database weighments and reports. Upon activation of this function

Página 50

- 143 - 28. COMMUNICATION Menu Communication is located in a menu group Parameters. It is accessed by pressing Setup key or < Setup > quick

Página 51 -  Non-standard printout

- 144 - Procedure: − Select < Wifi> communication interface, next set the parameters: • DHCP - Yes – No • IP Addresse - 1

Página 52

- 145 - To check selected network parameters press <Network status> field, you will see a window with the respective information: The select

Página 53 - 16. PARTS COUNTING

- 146 - 28.5. TCP protocol settings TCP, i.e.Transmission Control Protocol enables communicating two computers. The TCP operates in client-server mo

Página 54

- 147 - 29. PERIPHERAL DEVICES Menu PERIPHERAL DEVICES is located in menu group Parameters. It is accessed by pressing Setup key or < Setup &g

Página 55

- 148 - Additionally a given printout code page must be accordant with the printer code page. Code page accordance may be obtained as follows: • by

Página 56

- 149 - – function activated on moving to the Database of Products / Products / Product editing – press printer pictogram. Default values for each

Página 57

- 15 - 6. SOFTWARE STRUCTURE The structure of balance’s main menu is divided into function groups. Each group comprises parameters grouped by their

Página 58

- 150 - 29.3. Barcode scanner The balance enables cooperating with barcode scanners, which are used to quick searching for a product in the database

Página 59

- 151 - Procedure: • Connect a transponder card scanner to a balance’s port (RS 232 COM1 or RS 232 COM2), select communication port in balance set

Página 60 - 17. CHECKWEIGHING

- 152 - Ensuring correct cooperation between the balance and the ambient conditions module requires entering module connection address and the baud r

Página 61

- 153 - o Left door On changing the logic status of the input system, e.g. from [0] to [1] a function that is assigned to the system is carried o

Página 62 - 18. DOSING

- 154 - - Enter submenu < Inputs / Outputs>, select and press < Outputs> key - Enter editing mode of a selected output, which opens

Página 63

- 155 - 31. OTHER PARAMETERS This menu contains global parameters on balance operation, such as: language, date-time, beep sound, display calibra

Página 64

- 156 - 31.4. Volume The user may adjust power of the loudspeaker which is mounted in a read head: To adjust the volume: Press key, next select „

Página 65 - 19. PERCENT SETUP

- 157 - • Use finger or a thin (but not sharp edged) and soft stylus to press and hold a display area occupied by a cross. After pressing the fifth

Página 66

- 158 - 31.9. Sensor sensitivity The parameter is adjustable between 0 – 9, and it determines the distance from which the IR proximity sensors should

Página 67

- 159 - AUTOTEST FILTER It is process of 10 times loading and unloading of the internal weight for all possible settings of balance’s filter and val

Página 68

- 16 - 7. SOFTWARE WEIGHING WINDOW The software’s main window is divided into 4 main sections: • The upper part of the touch panel displays dat

Página 69 - 20. DENSITY

- 160 - Filter Very fast Value release Reliable

Página 70

- 161 - Test results: *Deviation for Max. *Value of repeatability of indication expressed as standard deviation *Result of door test (positive / neg

Página 71

- 162 - Autotest results can be exported by pressing <export> field on the level of all saved reports in a table. Data is sent to a data stora

Página 72

- 163 - 32. UPDATE The function contains two modules which enable updating: o Area of a user: SOFTWARE o Metrological parameters: WEIGHING MODUL

Página 73

- 164 - 34. MOVIES Option activating instructional movie explaining how to operate balance funtions. To view the movie go to <Movies> paramet

Página 74

- 165 - To play the movie the user has to: 1. Save the movie to the balance memory (see instruction above) 2. Enter <Movies> parameter grou

Página 75

- 166 - 35. COMMUNICATION PROTOCOL General information A. A character based communication protocol balance-terminal is designed for establishin

Página 76

- 167 - SS Result release IC Internal calibration IC1 Lock automatic internal adjustment IC0 Unlock automatic internal adjustment NB Give balance f

Página 77

- 168 - Accessible responses: Z_A CR LF Z_D CR LF - command understood and in progress - command carried out Z_A CR LF Z_^ CR LF - command understo

Página 78 - 21. ANIMAL WEIGHING

- 169 - Send stable measurement result in basic measuring unit Format: S CR LF Accessible responses: S_A CR LF S_E CR LF - command understood a

Página 79

- 17 - 8. LOGGING Full access to balance’s parameters and editing databases requires logging to instrument’s software as an operator with <Admini

Página 80

- 170 - MASS FRAME „P2” CR LF measuring unit from all weighing platforms Frame format with mass from each weighing platform: 1 2 3 4 5 6 7-15 1

Página 81 - 22. FORMULATION

- 171 - SUI_I CR LF - command understood but not accessible at this moment MASS FORMAT - mass value in current measuring unit is returned immedia

Página 82

- 172 - Switch off continuous transmission in current weighing unit Format: CU0 CR LF Accessible responses: CU0_I CR LF - command understood bu

Página 83

- 173 - Accessible responses: SM_OK CR LF SM_I CR LF - command carried out - command understood but not accessible at this moment (e.g.: other wor

Página 84

- 174 - Accessible responses: PROFILE OK CR LF - command understood, new PROFILE activated LOGIN ERRROR CR LF - command understood, an error in PROFI

Página 85

- 175 - Function not available for verified balances. Give balance factory number Format: NB CR LF Accessible responses: NB_A_”x” CR LF - command

Página 86

- 176 - If value greater than the valid one is given, the BEEP sound is activated for the maximal available time limit. Example Command: BP_350<

Página 87

- 177 - Example1 Command: OMI <CR><LF> – give available working modes Response: OMI <CR><LF> – available w

Página 88

- 178 - <CR><LF> given OMG_I <CR><LF> – command understood but not accessible at this moment n – parameter, decimal value s

Página 89

- 179 - Example: _ _ _ _ _ _ 1 8 3 2 . 0 _ g _ _ CR LF – a printout generated from a balance on pressing key, according to settings of <Weigh

Página 90 - 23. STATISTICS

- 18 - Below table indicates access to editing user parameters, databases and software functions depending on active access level. Authorization Ac

Página 91

- 180 - 37. DIAGRAMS OF CONNECTING CABLES Caution: Cable „Balance – Ethernet” is a regular network cable with slot jest RJ45 on both ends.

Página 92

- 181 - 38. ERROR MESSAGES Err2 Value beyond zero range, Err3 Value beyond tare range, Err8 Tarring / Zeroing operation time exceeded, -NUL

Página 93

- 182 - 40. APPENDIX A – Variables for printouts 40.1. List of variables Caution: Each of defined variables must be contained in braces:

Página 94 - 24. PIPETTE CALIBRATION

- 183 - {31} Weighing platform no. {32} Factory no. {33} Balance reading unit {34} Range {35} Parts counting: Mass of a standard {36} Percent s

Página 95

- 184 - {77} User: Access level {80} Packaging: Name {81} Packaging: Code {82} Packaging: Mass {85} Client: Name {86} Client: Code {87} Client: V

Página 96

- 185 - {177} Report on formulation: Sum {178} Report on formulation: Target value {179} Report on formulation: Difference {180} Report on formulatio

Página 97

- 186 - {275} Ambient conditions report: Date and time {276} Ambient conditions report: Temperature THB {277} Ambient conditions report: Humidity T

Página 98

- 187 - {319} Pipettes: Tested volumes {325} Pipette calibration report: Serial no. {326} Pipette calibration report: Start date {327} Pipette cali

Página 99

- 188 - {365} Weighing B: Interval {366} Weighing B: Difference {367} Weighing B: Difference % {368} Weighing B: Residue % {369} Weighing B: Number

Página 100 - Caution:

- 189 - Caution: 1) Format of variables {0} and {1} is finished with characters CR LF, (i.e. switching to a next line is carried out automaticall

Página 101

- 19 - 9.1. Terminal’s keyboard or Enter main menu Scroll menu upwards Scroll menu downwards, Fast up and down menu scrolling, Accept chang

Página 102

- 190 - Special formatting signs: Sign Description Example , Sign separating variables for formatting {7,10} – Net mass in adjustment unit with co

Página 103 - 25. DIFFERENTIAL WEIGHING

- 191 - Application list of formatted variables: CODE DESCRIPTION {7:V6.3} Net mass in EAN 13 code (6-character code) {7:V7.3} Net mass in EAN 13

Página 104 - - 104

- 192 - 41. APPENDIX D – Settings of CITIZEN printer Baud rate 9600b/sec Parity control none Bits 8bit Stop bits

Página 105 - - 105

- 193 - 43. APPENDIX F – Communication with barcode scanners 1. For communication with barcode scanners RADWAG balances 3Y series use RS232 inter

Página 106 - - 106

- 194 - 44. APPENDIX G – Menu structure User adjustment Description Value Internal adjustment Function External adjustment Function User adj

Página 107 - - 107

- 195 - − Pipettes − Pipette calibration reports − Series − Ambient conditions − Packages − Warehouses − Printouts − Universal variables − D

Página 108 - - 108

- 196 - » Printout template Settings » E2R System Settings Printer » Port COM 2 » Code page 1250 » Printouts Settings Barcode scanne

Página 109 - - 109

- 197 - Description Value Anonymous user » Guest Selection » User Selection » Advanced user Selection » Administrator Selection Date and

Página 110 - - 110

- 198 - MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG BALANCES AND SCALES POLAND, 26 – 600 Radom, 28 Bracka Street Phone. +

Página 111 - - 111

- 2 - AUGUST 2014

Página 112 - - 112

- 20 - 10. WEIGHING Load a weighed object on balance’s weighing pan. On stabilization of weighing result, indicated by stability marker visible o

Página 113 - - 113

- 21 - * - Accessibility of measuring units is conditioned by type of balance and its verification status. In non-verified balances all measuring un

Página 114 - - 114

- 22 - 10.3. Balance levelling Balance Y2 series features AutoLEVEL System, which continuously monitors balance’s level status during its operation.

Página 115 -  Standard printout

- 23 - 10.5. Tarring In order to determine net weight of a weighed object, place object’s container (packaging) on balance’s weighing pan, and on st

Página 116 - - 116

- 24 - 10.6. Use of air buoyancy compensation factor The application enables correcting mass measurement errors during: 1. Weighing loads that de

Página 117

- 25 - FUNCTIONING The application provides two ways to use the air buoyancy compensation procedure. 1. Inserting the specified value of air densi

Página 118

- 26 - value used for calculating buoyancy correction factor. Settings: VALUE – selecting this option opens a window for inserting determined va

Página 119 - - 119

- 27 - set to SAVE or SAVE & ALERTS mode, and there is no physical connection between a balance and a THB module, or the parameters for communica

Página 120 - − Declaring batch quantity

- 28 - indication returns to autozero zone, the software automatically deactivates Tare value. − Automatic footer printout Accessible options:

Página 121 - - 121

- 29 - − Printout Contains type of printout that is related to a working mode. Printout takes place on pressing PRINT key on balance’s overlay. Acc

Página 122 - - 122

- 3 - Table of Contents 1. GENERAL INFORMATION ... 8 2. UNPACKING AND INSTALLATION

Página 123 - 27. DATABASES

- 30 - Using <Minimum sample> mode guarantees that the results of completed weighing processes are within set tolerance limits, and they compl

Página 124 - - 124

- 31 - 6. Press <Method> field 7. Which opens a window containing a list of minimum sample methods stored in balance database. 8. Select

Página 125 - - 125

- 32 - - Mass above the set value of minimum sample for a given tare range Meaning of the pictograms of minimum sample mode: Mass below the set v

Página 126 - - 126

- 33 - If the option is on, the user shall notice an icon informing about specific mass printout format accepted by TITRATORS. The icon is located

Página 127

- 34 - 11. ADJUSTMENT Balances 3Y series feature automatic internal adjustment system which ensures correct measurement accuracy. Menu <ADJUSTME

Página 128

- 35 - • Acting according to the command, place an ordered weight/standard on balance’s weighing pan and press key, • On completing the adjust

Página 129

- 36 -  Time – adjustment takes place in time intervals declared in menu <Automatic adjustment time > (11.6)  Temperature – adjustment is t

Página 130 - - 130

- 37 -  dashes,  signature,  non-standard printout. 11.9. Adjustment history Contains data on all carried out adjustment processes. The recor

Página 131

- 38 - 12. USERS Menu “Users” contains list of balance operators, who are authorized to operate the instrument. The following data can be defined f

Página 132 - - 132

- 39 - 13. ACCESS LEVEL Access level in a balance determines scope of activities that a user can carry out. This menu can only be modified by bal

Página 133 - - 133

- 4 - 14.2.2. Working modes ... 43 14.2.3. Readout ...

Página 134

- 40 - Databases Balance Administrator is also authorized to set access level required to modifying each of the databases. Procedure: Enter grou

Página 135

- 41 - 14. PROFILES A Profile is a data pack determining: o functioning of working modes, e.g. parts counting, percent setup, etc., o what dat

Página 136

- 42 - Deleting a profile Procedure: • Enter balance’s main menu by pressing Setup key, • Enter submenu < Profiles>, • Press and hold an

Página 137 - • Save designed printout

- 43 - 14.2.2. Working modes On entering this option, the display opens a window containing all accessible working modes. The user can introduce the

Página 138

- 44 - Value release This parameter determines displaying the stability marker for a measurement result. There are 3 available settings of value

Página 139 - - 139

- 45 - Ambient conditions This parameter refers to ambient conditions of the balance. By default the parameter is set to value Stable but it is advi

Página 140

- 46 - 15. WORKING MODES – general information A balance 3Y series in its standard version features the following working modes: Weighing Means o

Página 141 - - 141

- 47 - Differential weighing Means of operation: analysis of mass sample change over time. Statistical Quality Control Working mode is intended to

Página 142 - - 142

- 48 - 3. Press corresponding menu item and select area for modification. Description of basic parameters accessible in <Settings>

Página 143 - 28. COMMUNICATION

- 49 - The selected option is recognized by the program and performed when activated by a particular motion. In order to ensure correct operation the

Página 144

- 5 - 22.4. Using formulas in weighing ... 85 22.5. Printouts ...

Página 145 - - 145

- 50 - create it. o HEADER − Dashes − Working mode − Date − Time − Balance type − Balance ID − User − Level status − Client − Warehouse −

Página 146 - - 146

- 51 - − GLP report − Signature − Non-standard printout BASIC PRINCIPLES OF USING PRINTOUTS 1. Press PRINT key on balance’s overlay to print va

Página 147 - 29. PERIPHERAL DEVICES

- 52 - 7. Use keyboard to design printout template, the printout may contain texts and variables. Caution:  User can add a printout by importing

Página 148 - - 148

- 53 - 16. PARTS COUNTING Working mode< Parts counting> enables determining quantity of small parts (objects) with equal part mass. Counting

Página 149 - - 149

- 54 - 16.1. Ustawienia dodatkowe związane z liczeniem detali The additional settings enable adjusting the working mode to user’s needs and requirem

Página 150

- 55 - Other functions of menu <Settings>: − Tare mode − Automatic footer printout − Printout mode / Value release − Printouts Means of

Página 151

- 56 - Caution: Remember: • Total mass of all parts loaded on the weighing pan must not exceed the maximal capacity (weighing range) of the b

Página 152 - 30. INPUTS / OUTPUTS

- 57 - 16.6. Updating part mass in the database Determined mass of a single part can be assigned to a product in the database of products. This opt

Página 153 - - 153

- 58 - 16.8. Checkweighing function in parts counting mode Proces liczenia detali może być wspomagany funkcją doważania czyli kontroli czy wskaza

Página 154 - - 154

- 59 - 16.9. Dosing function in parts counting mode Parts counting process can be aided by dosing function, i.e. control whether indication does not

Página 155 - 31. OTHER PARAMETERS

- 6 - 27.18.1. Export database of weighing records to file ... 139 27.18.2. Delete database ...

Página 156

- 60 - 17. CHECKWEIGHING Working mode< Checkweighing > enables controlling sample mass using two threshold (Low and High). Usually it is acc

Página 157 - - 157

- 61 - 17.1. Use of checkweighing thresholds Use of checkweighing thresholds can be carried out by: − Selection of Product < > for which Lo

Página 158 - - 158

- 62 - 18. DOSING Working mode< Dosing> enables carrying out the sampling process, until obtaining a pre-defined target mass. Worki

Página 159 - - 159

- 63 - 18.1. Use of database of products in dosing process When weighing, it is possible to use the value of target mass assigned to a product in th

Página 160 - - 160

- 64 - PROCEDURE 2 – manual inserting the value of target mass • Press < Target value > quick access key • In an opened window give the ta

Página 161 - - 161

- 65 - 19. PERCENT SETUP Working mode< Percent setup> enables comparing weighed load to a reference mass (standard). The process is expresse

Página 162

- 66 - 19.1. Comparison of sample and (reference) mass standard Comparison of samples with a mass standard can be carried out through: − Giving mas

Página 163 - 33. SYSTEM INFORMATION

- 67 - 19.2. Checkweighing, dosing functions in percent setup mode Percent setup mode can be aided by checkweighing and dosing functions. Access to

Página 164 - 34. MOVIES

- 68 - DOZOWANIE Uses the Target Value expressed in [%], which has to be reached during weighing (pouring) a sample. The target value also features a

Página 165 - - 165

- 69 - 20. DENSITY Working mode< Density > features three separate modules. The first one is used to determine density of solids, the second

Página 166 - 35. COMMUNICATION PROTOCOL

- 7 - 42. APPENDINX E - Settings of ZEBRA printers ... 192 43. APPENDIX F – Communication with barcode scanners ...

Página 167

- 70 - 20.1. Determining density of solid object Before starting the procedure, it is necessary to determine parameters of the process, such as: −

Página 168 - - 168

- 71 - 20.2. Determining density of liquid It is determining mass of a plunger if weighed in the air and in tested liquid. The density of tested

Página 169 - - 169

- 72 - 20.3. Density of air Density of air < > is a piece of information required to calculate correction of measurement result related to air

Página 170 - - 170

- 73 - 10. The balance automatically calculates the density of air, and indicates its value on the display, 11. Press < > key to finish the p

Página 171 - - 171

- 74 - out (if density has already been determined for this product, it is replaced with new value), o Tare mode, o Printout mode / Value release,

Página 172 - - 172

- 75 - Zawartość poszczególnych raportów: o SOLID − Working mode − Procedure − Sample no. − User − Balance type − Balance ID − Date − Time

Página 173 - - 173

- 76 - o AIR − Working mode − Procedure − Sample no. − User − Balance type − Balance ID − Date − Time − Mass of steel standard − Mass of a

Página 174 - - 174

- 77 - Use of data contained in the header and footer. Should data from header and/or footer be used, follow below procedure: o Press < Pri

Página 175 - - 175

- 78 - 21. ANIMAL WEIGHING Working mode< Animal weighing> enables reliable determining mass of objects in motion. In principle, this type of

Página 176 - - 176

- 79 - 21.1. Setting of animal working mode Depending on required mass analysis of weighed object, the balance enables setting internal criteria of

Página 177 - - 177

- 8 - 1. GENERAL INFORMATION INTENDED USE Balances 3Y series are intended to precise mass measurement of weighed loads conducted in laboratory co

Página 178 - - 178

- 80 - 21.2. Additional settings of animal weighing mode The additional settings enable adjusting the working mode to user’s needs and requirements.

Página 179

- 81 - 22. FORMULATION Working mode< Formulation> enables preparing mixtures out of several ingredients. The process is conducted automatical

Página 180 - ends

- 82 - On selecting the formulation mode, the display contains the following quick access keys in the bottom bar: 1. Setup – access to balance’s me

Página 181 - 39. ADDITIONAL EQUIPMENT

- 83 - TOLERANCE: balance software accepts mass of an ingredient if it is within set percent tolerance of total ingredient’s mass (±%) - (data acquir

Página 182 - - 182

- 84 - As each of ingredients must have its name and mass specified, the operator must know the exact composition of the total mixture. Adding a form

Página 183 - - 183

- 85 - 22.4. Using formulas in weighing In activating FORMULATION mode, depending on settings, user can move to formula making process either on s

Página 184 - - 184

- 86 - To proceed press < > key Caution: Formula making process can be aborted at any moment by pressing <Abort > key. PROCEDURE 2 –

Página 185 - - 185

- 87 - PROCEDURE 3 – Preparing a formulation that is saved in the Database of Formulas, with determining target mass of complete formulation. This p

Página 186 - - 186

- 88 - 22.5. Printouts Option Printouts enables setting the content of printouts in a standard printout and also determining non-standard printouts.

Página 187 - - 187

- 89 - 22.6. Report on completed formula making processes On completing any type of formula making process, a report is generated. The report is save

Página 188 - - 188

- 9 - • Balance defects, if service claims removing or destroying product’s protective stickers which protect the balance’s housing against unauthor

Página 189

- 90 - 23. STATISTICS Working mode< Statistics> enables acquiring data form a series of measurements and carrying out statistical calculati

Página 190 - - 190

- 91 - 23.1. Setting of keys and workspace for statistics mode When carrying out a series of measurements, bear in mind below data on operation of

Página 191 - - 191

- 92 - 23.3. Parameters related to a series of measurement Each series of measurements can be accompanied by the following options: previewing resul

Página 192 - - 192

- 93 - − Probability distribution chart – on selecting this option the software generates and displays chart of probability distribution for com

Página 193 - - 193

- 94 - 24. PIPETTE CALIBRATION Balance allows pipette calibration by means of a special balance software or by means of cooperation with computer s

Página 194 - - 194

- 95 - dosed by means of pipette through an opening located in the top cover of the weighing chamber. Thus prepared balance is ready for performance

Página 195 - - 195

- 96 - Before carrying out calibration process, load database with data on pipettes and calibration criteria. Adding pipettes can only be carried ou

Página 196 - - 196

- 97 - 3. Press <Settings> key, 4. The display indicates functions related to calibration of pipettes. Pipettes calibration is related to th

Página 197 - - 197

- 98 - The software automatically adds a new entry to the database, and enters its editing mode. Insert all parameters of a new formulation. List

Página 198 - - 198

- 99 -  Standard printout Comprises four internal sections featuring different variables. For each variable set option YES to include it in a sta

Comentários a estes Manuais

Sem comentários