Radwag MAX 60 Moisture Analyzer Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Instrumentos de medida Radwag MAX 60 Moisture Analyzer. RADWAG MAX 60 Moisture Analyzer User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 88
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
User manual no.:
IMMU-11-02-03-14-ENG
MOISTURE
ANALYZER
MAX
SERIES
BALANCES AND SCALES
RADWAG 26 600 Radom, Bracka 28, POLAND
Phone: +48 (0-48) 38 48 800, fax. +48 (0-48) 385 00 10
export@radwag.com
www.radwag.com
Vista de página 0
1 2 3 4 5 6 ... 87 88

Resumo do Conteúdo

Página 1 - ANALYZER

User manual no.: IMMU-11-02-03-14-ENG MOISTURE ANALYZER MAX SERIES BALANCES AND SCALES RADWAG 26 – 600 Radom, Bracka 28,

Página 2

- 10 - Under no circumstances can the instrument be left Unsupervised! WARNING: Substances containing toxic and caustic or corrosive components

Página 3 - TABLE OF CONTENTS

- 11 - 2.4. Inappropriate use CAUTION! Do not open the drying chamber during drying process. Moisture analyzer features a halogen lamp which is a v

Página 4

- 12 - - protect moisture analyzer against contacts with liquids, it might lead to electrocution, fire, emission of substances containing toxic or c

Página 5

- 13 - 2.9.1. Protective clothing The use of protective clothing is highly recommended while working with the instrument in order to take safety pr

Página 6

- 14 - 3. TRANSPORT AND STORAGE 3.1. Delivery check Please check the packaging immediately upon delivery and the device during unpacking for any vi

Página 7

- 15 - 4.2. Unpacking Carefully remove the moisture analyzer from its packaging, remove the plastic and foil transport protective elements. Gently p

Página 8

- 16 - 4.3. Level setting Before plugging to mains, level the moisture analyzer using adjustable feet. Turn the feet in a way that the air bubble of

Página 9

- 17 - 4.7. Connecting peripheral equipment The moisture analyzer must be unplugged from the mains before connecting or disconnecting any peripheral

Página 10

- 18 - On/Off key – switch on/off display of moisture analyzer. On switching off the display of the device, other subassemblies are continuously s

Página 11

- 19 - P1 Adjustment P1 01 External adjustment P1 02 User adjustment P1 03 Adjustment test P1 04 Temperature adjust. P1 05 Adjustment report print

Página 12

- 2 - MARCH 2014

Página 13

- 20 - 7.1. Menu operation using moisture analyzer keyboard Entering option of selecting a drying mode: Press Test Menu key to open a list with d

Página 14

- 21 - or name) when its value is flashing. Use RIGHT / LEFT navigating arrows to select a character while entering a parameter value (while its

Página 15

- 22 - On making all changes in the parameter settings, exit to main menu by pressing the ESC key for a few times, until the software displays a mess

Página 16

- 23 - 8. USER MENU User menu is accessible on pressing SETUP key on moisture analyzer’s overlay. The user enables: moisture analyzer adjustment, se

Página 17

- 24 - The moisture analyzer gives a command on determining mass of an empty pan, followed by a command to place a 50 g weight (standard) on the

Página 18

- 25 - The moisture analyzer gives a command on determining mass of an empty pan, followed by a command to place a weight with pre-determine

Página 19

- 26 - 1. Thermometer 2. Thermometer holder with a shield Adjustment is a simple process aimed at adjusting the temperature sensor assembled in

Página 20

- 27 - Step 2. Place in the drying chamber the components of the temperature adjustment set: • Drying chamber shield with assembled control therm

Página 21

- 28 - Enter menu group P1 Adjustment. Set the marker next to a parameter 04 Temperature adjustment. Press RIGHT ARROW navi

Página 22

- 29 - P1 05 Report printout : 1 : YES – report is printed P1 05 Report printout: 0 : NO – report is not printed Remember that on enabling report

Página 23

- 3 - TABLE OF CONTENTS 1. TECHNICAL DATA ... 6 2. GENERAL SAFETY INFOR

Página 24

- 30 - Press RIGHT ARROW navigating key. The moisture analyzer opens a window for entering the temperature value for carrying out the drying

Página 25

- 31 - ---------------------------------------- Test the drying chamber

Página 26

- 32 - and enter the following character. On entering all of the characters press ENTER key. Using external computer keyboard PS/2 type Press F2 k

Página 27

- 33 - Data to be printed must have an attribute set to “1 yes”. EXAMPLES OF PRINTOUTS FOR DIFFERENT GLP SETTINGS: P2 03 print time: 1:yes P2 04

Página 28

- 34 - 8.3.2. Setting time format Press navigating arrow key to enter submenu 02 Time format. Select one of available values: 1. Time format – 12 h

Página 29

- 35 - After setting the time to a needed value return to the weighing mode following procedure described in point 7.1 of this user manual. 8.3.4.

Página 30

- 36 - 8.4.2. Filter settings Depending on current ambient conditions at a workstation it is necessary to set filtering value. In case of perfect op

Página 31

- 37 - 8.5. RS 232 Functions Moisture analyzer MAX series enables determining communication parameters with a computer or a printer. Enter menu gr

Página 32

- 38 - 8.6. Printouts User of a moisture analyzer MAX series can set up to 5 different printout templates which are sent from the instrument to a

Página 33

- 39 - 8.6.2. Non-standard printout templates Principles of creating non-standard printout templates: 1. Moisture analyzer MAX series enables cre

Página 34

- 4 - 8.2.1. User ... 31 8.2.2. Project ...

Página 35

- 40 - Variables available in drying mode only %C Drying chamber temperature %c Drying time %M Drying result – humidity content %S Start mass of a

Página 36

- 41 - Load mass *****Signature:... ***<active working mode >*** Enter text strings settings and input 8 characters from the

Página 37

- 42 - Principles of inserting texts: a) Using keys on balance’s overlay Toggling upwards through all available characters: digits, letters, and

Página 38

- 43 - 8.6.5. Enabling non-standard printout templates Enabling a non standard printout template, e.g. printout no. 1: Enter group of parameters P6

Página 39

- 44 - Printout 4 8.7. Moisture analyzer parameter settings. Depending on user needs the moisture analyzer enables setting parameters influenci

Página 40

- 45 - 8.7.2. Parameter settings The parameters are set as specified in case of previous menu groups. 01 Password The password protects the mois

Página 41

- 46 - 08 Balance no. This function serves for information purpose only, and it enables previewing factory number of a balance 09 Software no. E

Página 42

- 47 - Determines whether a code entered to moisture analyzer’s memory should be automatically sent via RS 232 interface. 14. Previous version The p

Página 43

- 48 - Press navigating arrow keys to set the cursor next to a menu group P7 Other. On returning to the main window (wit

Página 44

- 49 - Press right arrow navigating key to enable selection of a drying profile (name of a drying mode is previewed above the mode’s graphic

Página 45

- 5 - 10.10. Restore default setting ... 64 10.11. Printout of software settings ...

Página 46

- 50 - parameters. Pressing the arrow key causes appearing of a cursor (black triangle) next to the first parameter of selected drying mode (visible

Página 47

- 51 - After setting the Finish mode criteria go to setting the following parameters of a drying process. In order to set other

Página 48

- 52 - After setting the Result criterion go to setting the following parameters of a drying process. In order to set other parameters

Página 49

- 53 - sample to be tested. In order to finish setting the drying mode parameters and go to the humidity content determining process press ENTER ke

Página 50

- 54 - Place the disposable drying pan in its intended holder and place the assembly on the cross-shaped support. support. The display indicates ma

Página 51

- 55 - Place a sample to be tested on the drying pan. Mass of a sample should be selected according to previously conducted experiments and featur

Página 52

- 56 - The indications on the display change and indicate data on conducted process. The moisture analyzer automatically carries out the drying pro

Página 53

- 57 - 10. DRYING PROCESS WITH USE OF DRYING PROGRAM LIBRARY This section of the user manual specifies in details the procedures for determining a n

Página 54

- 58 - a drying program entry to be filled with data. Press RIGHT arrow navigating key to open an entry with data on drying program. The open

Página 55

- 59 - After entering the new name accept it by pressing ENTER key. The last entered character stops flashing. After accepting the newly entered

Página 56

- 6 - 1. TECHNICAL DATA Type MAX 50/1 MAX 50 MAX 60 Reading interval 0,1 mg 1 mg Max. capacity 50 g 60 g Reading interval of moisture content

Página 57

- 60 - analyzer Set drying temperature for drying mode Mild and time in which the moisture analyzer should reach the set temperature value.

Página 58

- 61 - 10.5. Auto switch off settings Finishing of a drying mode can be carried out as: - Automatic 1 (change ratio 1mg/10s) - Automatic 2 (change

Página 59

- 62 - 10.7. Setting printout interval This parameter determines the interval of sending a measurement result on humidity content of a tested sampl

Página 60

- 63 - In case option Optional is enabled the user has to enter required sample mass and tolerance value for the material to be weighed / dried. If

Página 61

- 64 - Procedure: Go to software menu. Use DOWN navigating arrow key to place the cursor (black triangle) next to a parameter Corrective Coef

Página 62

- 65 - software moves back to the previous window. Pressing Esc key abandons restoring of the default parameter. The software returns to previ

Página 63

- 66 - Press RIGHT arrow navigating key causes displaying a message to confirm printout of parameters. Press ENTER key to accept the proc

Página 64

- 67 - 10.12. Saving drying mode settings in moisture analyzer’s permanent memory When determining parameters of a drying mode, all the settings ar

Página 65

- 68 - 11. TESTING PROCEDURE USING A DRYING PROGRAM FROM THE LIBRARY OF DRYING PROGRAMS A moisture analyzer MAX series enables carrying out a drying

Página 66

- 69 - Press ENTER key to return to the main window. The moisture analyzer is ready to start testing procedure with programmed drying parameters

Página 67

- 7 - 2. GENERAL SAFETY INFORMATION 2.1. Definitions of signals and warning signs Safety precautions are marked with special descriptions and warn

Página 68

- 70 - heating a sample (with application of a halogen filament) carried out by a moisture analyzer, makes the measurement process very time efficien

Página 69

- 71 - can be prepared for measurement otherwise than grinding, any possible moisture content loss should be calculated. Use of high-silica sand Ens

Página 70

- 72 - Liquid substances Semi-fluid substances are dried in their natural form. Large amount of grease (fat) occurring in some of substances make moi

Página 71

- 73 - Sample mass has considerable influence on repeatability of measurement results obtained on a moisture analyzer. Relation between sample mass

Página 72

- 74 - 13.4. Selecting a drying mode The software of moisture analyzer MAX series enables selecting one of four drying modes: • Standard • Quick •

Página 73

- 75 - 13.5. Selecting drying time Drying time is set by selecting one of available finish mode criteria. This means that a moisture analyzer must m

Página 74

- 76 - 13.6. Drying mode analysis In the first case the drying mode is an asymptote. The humidity content in a sample reaches a constant and it does

Página 75

- 77 - 14. COOPERATION WITH A PRINTER OR A COMPUTER Each pressing of < PRINT > key causes sending to a connected printer or computer a signal

Página 76

- 78 - 15. LIST OF COMMANDS COMPUTER - BALANCE Function INTERFACE RESET Command R CR LF (zeroing currently carried out commands, restoring factor

Página 77

- 79 - Function GIVE SOFTWARE REVISION Command RV CR LF (sends software name) Function GIVE OR CHANGE DATE IN A BALANCE Command PD CR LF (causes

Página 78

- 8 - Flammable or explosive substances Toxic substances Hot surfaces 2.2. Safety information CAUTION! The use of moisture analyzer MA 3Y re

Página 79

- 80 - 16. USER GUIDELINES The measurement of relative humidity content of materials to be tested using a moisture analyzer MAX series is much short

Página 80 - • Drying time

- 81 - 17. MOISTURE ANALYZER MAINTENANCE ACTIVITIES This section of the user manual describes procedures of maintaining a moisture analyzer MAX seri

Página 81

- 82 - After cleaning, thoroughly dry each of moisture analyzer’s components. Do not allow any contamination or liquid to fall into the moisture anal

Página 82

- 83 - 17.3. Replacing the fuses If after plugging to mains, a signal diode on moisture analyzer’s display does not light up (lack of any reaction o

Página 83

- 84 - 17.4. Troubleshooting Problem: no reaction to pressing main switch on/off key (display remains dark). Probable cause: − No voltage in mai

Página 84

- 85 - 17.5. Error messages Detecting of an error is signaled by the moisture analyzer by displaying a message corresponding to the error. The messa

Página 85

- 86 - adjustment coefficient by more than 20% "Out of range " 3.1 Parameter value exceeds permissible value. "Incorrect value "

Página 86

- 87 - The data is ordered according to its performance schedule. If a measurement was carried out using the Mode from Database, then next to the me

Página 87 - IMMU-11-02-03-14-ENG

- 88 - MANUFACTURER OF ELECTRONIC WEIGHING INSTRUMENTS RADWAG WAGI ELEKTRONICZNE 26 – 600 Radom, Bracka Street 28, Poland Phone. +48

Página 88 - MANUFACTURER

- 9 - overheating. Leave about 20 cm around the instrument and about 1 m above. Air vents that are located in the housing cannot be covered, sealed

Comentários a estes Manuais

Sem comentários