14.1. Setting means of auto switch off mode
Parameter switch off mode can take the following values:
1 automatic finish (mass change 1mg / in 10s time)
2 automatic finish (mass change 1mg / in 25s time)
3 automatic finish (mass change 1mg / in 60s time)
4 automatic finish (mass change 1mg / in 90s time)
5 automatic finish (mass change 1mg / in 120s time)
- manual finish (on pressing Start/Stop key)
Maximal time interval of the drying process cannot be longer than 9
hours 59 minutes. After this time the process will be automatically
switched off.
- time defined (max time setting 9 hours 59 minutes):