Radwag MAC 210 Moisture Analyzer Manual do Utilizador Página 43

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 60
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 42
43
13.3. Printout interval
Printout interval determines how often data on drying process is sent through
RS 232 port. Available settings: 1, 2, 3, 5, 10, 20, 30, 60, 120, 180 seconds
(setting <---> results in printing only a header and a footer respectively,
drying process start and drying process end, halfway results are not printed
line).
13.4. Determining range of data sent during drying process
YES - data limited to drying process result only (printout of a single
like).
no - printout of complete report from drying process: header, line,
footer.
Vista de página 42
1 2 ... 38 39 40 41 42 43 44 45 46 47 48 ... 59 60

Comentários a estes Manuais

Sem comentários